Error : The opatch Applicable check failed. The patch /tmp/19380115/19121549 is not applicable to /app/grid
Error:Patch Applicable check failed for /app/grid
SOLUTION : unset ORA_CRS_HOME , unset ORA_ASM_HOME
chown -R oracle:oinstall /tmp/19380115
You've got to have a dream. When you lose your dreams, you die.
2014-11-27
has a disk HB, but no network HB, DHB has rcfg
11gR2 GI Node May not Join the Cluster After Private Network is Functional After Eviction due to Private Network Problem (Doc ID 1479380.1)
2014-11-26
do not use ext4 for oracle database files
http://kevinclosson.net/2012/03/06/yes-file-systems-still-need-to-support-concurrent-writes-yet-another-look-at-xfs-versus-ext4/
2014-11-25
has a disk HB, but no network HB, DHB has rcfg
http://sqlsewer.blogspot.ro/2013/07/oracle-crs-is-not-starting-has-disk-hb.html
But if Ping and SSH did work between nodes via interconnect interface and still ocssd log did complain about interconnect HeartBeat (no network HB) then interconnect interface is jammed. You can try to restart it to get it fixed (NOTE! It is usually the working node interconnect interface that is needed to restart (like error message is saying in ocssd.log (it is complaining node1)). For example if node2 CRS is not starting then restart node1 interconnect interface ) :
[root@<node1> <node1>]# ifdown eth1
[root@<node1> <node1>]# ifup eth1
And check that eth1 is looking ok:
[root@<node1> <node1>]# ifconfig
See also http://oradbastuff.blogspot.ro/2014/11/has-disk-hb-but-no-network-hb-dhb-has_27.html
Best idea : upgrade Gi to 11.2.0.4
But if Ping and SSH did work between nodes via interconnect interface and still ocssd log did complain about interconnect HeartBeat (no network HB) then interconnect interface is jammed. You can try to restart it to get it fixed (NOTE! It is usually the working node interconnect interface that is needed to restart (like error message is saying in ocssd.log (it is complaining node1)). For example if node2 CRS is not starting then restart node1 interconnect interface ) :
[root@<node1> <node1>]# ifdown eth1
[root@<node1> <node1>]# ifup eth1
And check that eth1 is looking ok:
[root@<node1> <node1>]# ifconfig
See also http://oradbastuff.blogspot.ro/2014/11/has-disk-hb-but-no-network-hb-dhb-has_27.html
Best idea : upgrade Gi to 11.2.0.4
2014-11-17
ord
„Adevărata libetate n-are nimica de-a face cu neregula şi anarhia: fără datorii nu există drepturi, fără ordine nu-i libertate“.
how to measure latency and iops on netapp volumes
stats show -i 1 -n 10 -e volume:*:latency
stats show -i 2 -n 10 -e volume:*:ops
stats show -i 1 -n 10 -e system:system:ops
2014-11-11
problems with 4 TB hard drive in B110i raid controller
The Smart Array B110i controller is not compatible with drives larger than 2TB in RAID. It's not well-documented or noted online, but you've run into a product limitation. Remember, this controller predates the introduction of 4TB disks by a bit.
If you need to use those specific 3rd party disks, then you're going to have to swap controllers or use software RAID.
serverfault.com
custom ssd for proliant
http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/Custom-SSD-Drives-in-Proliant-DL380/td-p/5804993#.VGHlEfmsUbg
http://serverfault.com/questions/528875/third-party-ssd-solutions-in-proliant-gen8-servers/528989#528989
http://serverfault.com/questions/521393/are-there-any-san-vendors-that-allow-third-party-drives/521395#521395
http://serverfault.com/questions/528875/third-party-ssd-solutions-in-proliant-gen8-servers/528989#528989
http://serverfault.com/questions/521393/are-there-any-san-vendors-that-allow-third-party-drives/521395#521395
2014-11-10
2014-11-07
check number of files in a folder
http://serverfault.com/questions/192158/use-nagios-to-monitor-files-in-folders
Note : inside the script, you must modify the maxdepth from 1 to 3 ( or whateever you want )